{"product_id":"dre-standard-centrifuge-dr-119-copy","title":"DRE Microhematocrit Centrifuge - DR-118","description":"\u003ch2\u003eDRE Microhematocrit Centrifuge - DR-118\u003c\/h2\u003e\n\u003cp\u003eThe DRE Microhematocrit Centrifuge - DR-118 is the ideal centrifuge for general laboratory purposes, specifically designed for capillary use. This centrifuge features a timer-activated operation that can be adjusted from 0 to 60 minutes, ensuring precise control. Constructed from heavy-gauge steel with rubber suction feet, it provides stability during operation by preventing creeping and movement. With a safety latch, inner switch shut-off, and a sophisticated modular electronic circuit, this centrifuge combines durability with user-friendly features.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSafety latch and inner switch shut-off are standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHolds 24 slides\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNew unit sold by DRE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUsed exclusively for capillary purposes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccommodated with rotor (F-2415) for 24 capillary tubes of 1.5 ml (75x1.5 mm O.D.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety power shutoff lid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety latch and lock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic brake to complete stop in 13 seconds when the timer expires\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum speed of 12000 rpm and maximum RCF of 14490 x g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReader disc included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSophisticated modular electronic circuit for easy handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for laboratory use in HT, Routine, and Jaundice testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNet Weight: 7.6 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTimer: 0-60 minutes (spring-operated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-02i2{background-color:#FFF;border-color:#000000;color:#1A1A1A;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-iaot{background-color:#ffffff;border-color:#000000;color:#1a1a1a;text-align:left;vertical-align:top}\n.tg .tg-hd8l{background-color:#FFF;border-color:#000000;color:#1A1A1A;text-align:left;vertical-align:top}\n.tg .tg-e7qq{background-color:#ffffff;border-color:#000000;color:#1a1a1a;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-v0nx{background-color:#ffffff;border-color:#000000;color:#1a1a1a;text-align:left;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable style=\"width: 99.9987%; height: 96.9165px;\" class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003cth style=\"width: 22.6425%; height: 19.5833px;\" class=\"tg-02i2\"\u003eMaximum Speed:\u003c\/th\u003e\n\u003cth style=\"width: 73.0852%; height: 19.5833px;\" class=\"tg-hd8l\"\u003e12000 rpm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 22.6425%; height: 19.5833px;\" class=\"tg-e7qq\"\u003eRotor:\u003c\/td\u003e\n\u003ctd style=\"width: 73.0852%; height: 19.5833px;\" class=\"tg-iaot\"\u003eA-0815 for 8 x 10ml testing tubes or 4 x 15ml tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5833px;\"\u003e\n\u003ctd style=\"width: 22.6425%; height: 18.5833px;\" class=\"tg-02i2\"\u003eMaximum RCF:\u003c\/td\u003e\n\u003ctd style=\"width: 73.0852%; height: 18.5833px;\" class=\"tg-iaot\"\u003e14490 x g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 22.6425%; height: 19.5833px;\" class=\"tg-02i2\"\u003eTimer:\u003c\/td\u003e\n\u003ctd style=\"width: 73.0852%; height: 19.5833px;\" class=\"tg-iaot\"\u003eMechanical 60-minute timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 22.6425%; height: 19.5833px;\" class=\"tg-02i2\"\u003e\u003cstrong\u003eRotor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 73.0852%; height: 19.5833px;\" class=\"tg-v0nx\"\u003eF-2415 for 24 capillary tubes of 1.5 ml (75x1.5 mm O.D.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat Our Experts Think\u003c\/h5\u003e\n\u003cp\u003eThe DRE Microhematocrit Centrifuge (DR-118) is an essential tool for veterinary labs, providing quick and accurate hematocrit readings. Its compact design and reliable performance make it ideal for routine diagnostics:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Performance\u003c\/strong\u003e: Rapidly separates blood samples for precise hematocrit measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e: Space-saving construction is perfect for small veterinary practices or labs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Build\u003c\/strong\u003e: Sturdy materials ensure consistent performance and longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Features\u003c\/strong\u003e: Equipped with a secure lid-locking system to protect users during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to Operate\u003c\/strong\u003e: User-friendly controls simplify daily use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is this centrifuge used for?\u003c\/strong\u003e\u003cbr\u003eA: It is primarily used for determining the hematocrit (packed cell volume) in blood samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How fast does it operate?\u003c\/strong\u003e\u003cbr\u003eA: The centrifuge offers high-speed rotation for efficient separation in minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it safe to use?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes a lid-locking mechanism and other safety features to ensure secure operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it handle multiple samples at once?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is designed to accommodate multiple capillary tubes simultaneously for efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it easy to clean?\u003c\/strong\u003e\u003cbr\u003eA: Absolutely, its compact and simple design allows for quick cleaning and maintenance.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean After Use\u003c\/strong\u003e: Wipe down the rotor and chamber with a soft, damp cloth and approved cleaning solution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect for Wear\u003c\/strong\u003e: Regularly check the lid lock and rotor for signs of wear or damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibrate Periodically\u003c\/strong\u003e: Ensure the centrifuge is calibrated to maintain accurate performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLubricate Moving Parts\u003c\/strong\u003e: Use manufacturer-recommended lubricant to keep the rotor running smoothly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStore Properly\u003c\/strong\u003e: Place in a clean, dry location when not in use to prevent dust buildup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"DRE VETERINARY","offers":[{"title":"Default Title","offer_id":53512051425591,"sku":"DR-118","price":825.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0936\/2030\/6231\/files\/dre-standard-centrifuge-dr-119-copy-1_turbo.webp?v=1793787008","url":"https:\/\/zyvre.com\/products\/dre-standard-centrifuge-dr-119-copy","provider":"Zyvre","version":"1.0","type":"link"}